{"id":8594,"date":"2022-06-27T10:23:23","date_gmt":"2022-06-27T10:23:23","guid":{"rendered":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/?post_type=blog&#038;p=8594"},"modified":"2023-01-15T16:27:09","modified_gmt":"2023-01-15T16:27:09","slug":"how-do-we-carry-out-an-air-leakage-test-for-pas2035","status":"publish","type":"blog","link":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/","title":{"rendered":"How do we carry out an Air Leakage Test for PAS2035?"},"content":{"rendered":"<p style=\"text-align: left;\">Our blower door system can be set up quite quickly to undertake <a href=\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/air-tightness-testing-for-pas2035\/\">air tightness testing on PAS2035<\/a> buildings. This means we can quickly ascertain the buildings air leakage rate and let you the results on the same day.<\/p>\n<p style=\"text-align: left;\">Basically, our blower door fan mounts into a door-sized housing, that can be adjusted to suit the size of the door frame. We then set up the <a href=\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/what-is-air-tightness-testing-or-or-blower-door-testing\/\">blower door equipment<\/a> as follows.<\/p>\n<ol style=\"text-align: left;\">\n<li style=\"list-style-type: none;\">\n<ol>\n<li style=\"list-style-type: none;\">\n<ol>\n<li style=\"list-style-type: none;\">\n<ol>\n<li style=\"list-style-type: none;\">\n<ol>\n<li style=\"list-style-type: none;\">\n<ol>\n<li style=\"list-style-type: none;\">\n<ol>\n<li>We will temporarily install a blower door fan system (depending on building size) in a suitably placed doorway. If it\u2019s a very large building we may need to use a multiple fan system.<\/li>\n<li>We then take a series of environmental measurements such as internal and external temperatures as well as barometric pressures.<\/li>\n<li>We then turn on the fan equipment and take measurements between 25-70Pa in 5Pa increments, recording the pressure differential at each step.<\/li>\n<li>We then take a second series of environmental measurements such as internal and external temperatures as well as barometric pressures.<\/li>\n<li>Finally, our technicians will calculate the total air flow required to achieve a pressure differential of 50 Pa, divided by the total building envelope area &#8211; this calculation will show leakage rate in m\u00b3\/h.m\u00b2 @ 50 Pa.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<p style=\"text-align: left;\">We usually allow two to three hours to complete each air tightness and <a href=\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/smoke-leakage-surveys-to-pass-air-tightness-testing\/\">smoke leakage test<\/a>; however, we can attend site all day if the building looks very leaky.<\/p>\n<p style=\"text-align: left;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-8595 aligncenter\" src=\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-content\/uploads\/2022\/06\/Air-Tightness-Test-PAS2025-600x450.jpg\" alt=\"Air-Tightness-Test-Pas2035\" width=\"600\" height=\"450\" \/><\/p>\n<p style=\"text-align: left;\">\n<h2 style=\"text-align: left;\"><strong>We can help with your PAS2035 Air Tightness Test <\/strong><\/h2>\n<p style=\"text-align: left;\">You can rest assured that we provide the highest quality service for all your air tightness testing and reportage. We are a UKAS accredited laboratory, as well as being certified to ATTMA Level 2.<\/p>\n<p style=\"text-align: left;\">If you would like more information in for our <a href=\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/air-tightness-testing-for-pas2035\/\">PAS 2035 air tightness testing<\/a> services, please contact us at info@airpressuretesting.net\u00a0 or visit our call us on 01525 303905. Alternatively, please see a copy of our air leakage checklist to help you prepare for your PAS2035 Air Test.<\/p>\n","protected":false},"featured_media":9553,"template":"","class_list":["post-8594","blog","type-blog","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How do we carry out an Air Leakage Test for PAS2035? | APT Sound Testing<\/title>\n<meta name=\"description\" content=\"Our blower door systems can be set up quickly to undertake air tightness testing on PAS2035 buildings throughout London and the South East\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How do we carry out an Air Leakage Test for PAS2035? | APT Sound Testing\" \/>\n<meta property=\"og:description\" content=\"Our blower door systems can be set up quickly to undertake air tightness testing on PAS2035 buildings throughout London and the South East\" \/>\n<meta property=\"og:url\" content=\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/\" \/>\n<meta property=\"og:site_name\" content=\"APT Sound Testing\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/aptsoundtesting\/\" \/>\n<meta property=\"article:modified_time\" content=\"2023-01-15T16:27:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-content\/uploads\/2022\/06\/Air-Tightness-Test-PAS2025.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"640\" \/>\n\t<meta property=\"og:image:height\" content=\"480\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/\",\"url\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/\",\"name\":\"How do we carry out an Air Leakage Test for PAS2035? | APT Sound Testing\",\"isPartOf\":{\"@id\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#website\"},\"datePublished\":\"2022-06-27T10:23:23+00:00\",\"dateModified\":\"2023-01-15T16:27:09+00:00\",\"description\":\"Our blower door systems can be set up quickly to undertake air tightness testing on PAS2035 buildings throughout London and the South East\",\"breadcrumb\":{\"@id\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How do we carry out an Air Leakage Test for PAS2035?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#website\",\"url\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/\",\"name\":\"APT Sound Testing\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#organization\",\"name\":\"APT Sound Testing\",\"url\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-content\/uploads\/2022\/05\/apt-logo.png\",\"contentUrl\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-content\/uploads\/2022\/05\/apt-logo.png\",\"width\":203,\"height\":55,\"caption\":\"APT Sound Testing\"},\"image\":{\"@id\":\"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/aptsoundtesting\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How do we carry out an Air Leakage Test for PAS2035? | APT Sound Testing","description":"Our blower door systems can be set up quickly to undertake air tightness testing on PAS2035 buildings throughout London and the South East","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/","og_locale":"en_GB","og_type":"article","og_title":"How do we carry out an Air Leakage Test for PAS2035? | APT Sound Testing","og_description":"Our blower door systems can be set up quickly to undertake air tightness testing on PAS2035 buildings throughout London and the South East","og_url":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/","og_site_name":"APT Sound Testing","article_publisher":"https:\/\/www.facebook.com\/aptsoundtesting\/","article_modified_time":"2023-01-15T16:27:09+00:00","og_image":[{"width":640,"height":480,"url":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-content\/uploads\/2022\/06\/Air-Tightness-Test-PAS2025.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/","url":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/","name":"How do we carry out an Air Leakage Test for PAS2035? | APT Sound Testing","isPartOf":{"@id":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#website"},"datePublished":"2022-06-27T10:23:23+00:00","dateModified":"2023-01-15T16:27:09+00:00","description":"Our blower door systems can be set up quickly to undertake air tightness testing on PAS2035 buildings throughout London and the South East","breadcrumb":{"@id":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/blog\/how-do-we-carry-out-an-air-leakage-test-for-pas2035\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/"},{"@type":"ListItem","position":2,"name":"How do we carry out an Air Leakage Test for PAS2035?"}]},{"@type":"WebSite","@id":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#website","url":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/","name":"APT Sound Testing","description":"","publisher":{"@id":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#organization","name":"APT Sound Testing","url":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#\/schema\/logo\/image\/","url":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-content\/uploads\/2022\/05\/apt-logo.png","contentUrl":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-content\/uploads\/2022\/05\/apt-logo.png","width":203,"height":55,"caption":"APT Sound Testing"},"image":{"@id":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/aptsoundtesting\/"]}]}},"_links":{"self":[{"href":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-json\/wp\/v2\/blog\/8594","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-json\/wp\/v2\/media\/9553"}],"wp:attachment":[{"href":"https:\/\/createdbyadam.co.uk\/aptsoundtesting\/wp-json\/wp\/v2\/media?parent=8594"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}